Am J Physiol Cell Physiol Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Cell Physiol 267: C1027-C1035, 1994;
0363-6143/94 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Coombs, H. V.
Right arrow Articles by Sanders, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Coombs, H. V.
Right arrow Articles by Sanders, D.

AJP - Cell Physiology, Vol 267, Issue 4 C1027-C1035, Copyright © 1994 by American Physiological Society


ARTICLES

Disruptive effects of protein on performance of liquid membrane-based ion-selective microelectrodes

H. V. Coombs, A. J. Miller and D. Sanders
Biology Department, University of York, Heslington, United Kingdom.

The effects of addition of protein [bovine serum albumin (BSA)] to the calibration solutions of various liquid membrane-based ion-selective microelectrodes have been assessed. Protein at typically cytosolic levels of 100 mg/ml had no effect on the response of Na(+)-, K(+)-, Mg(2+)-, Ca(2+)-, H(+)-, NO3(-)-, and Cl(-)- selective microelectrodes at ion concentrations well above the respective detection limits. By contrast, this level of protein resulted in a pronounced increase in the detection limits of Na(+)-, K(+)-, Mg(2+)-, Ca2+, and Cl(-)-selective microelectrodes; H+ and NO3- microelectrodes were largely unaffected by the protein. The effect of BSA on detection limit is independent of pH and ionic strength, nor is it due to hysteresis, to binding of ions to the protein, or to the generation of junction potentials. More extensive studies on Na(+)-selective microelectrodes revealed that other proteins and large molecules (e.g., polyethylene glycol) also increase detection limits, with the extent of this effect apparently correlated positively with the molecular weight. Because biological macromolecules at physiological concentrations can influence the properties of alkali- and alkali earth cation-selective microelectrodes, care must be taken if the use of these electrodes entails cytosolic measurements close to their detection limits.


This article has been cited by other articles:


Home page
Plant Physiol.Home page
S. Shabala, V. Demidchik, L. Shabala, T. A. Cuin, S. J. Smith, A. J. Miller, J. M. Davies, and I. A. Newman
Extracellular Ca2+ Ameliorates NaCl-Induced K+ Loss from Arabidopsis Root and Leaf Cells by Controlling Plasma Membrane K+-Permeable Channels
Plant Physiology, August 1, 2006; 141(4): 1653 - 1665.
[Abstract] [Full Text] [PDF]


Home page
J Exp BotHome page
D. E. Carden, D. Diamond, and A. J. Miller
An improved Na+-selective microelectrode for intracellular measurements in plant cells
J. Exp. Bot., June 1, 2001; 52(359): 1353 - 1359.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online